Air pressure alarm sensor assembly3
Release time:2025-08-28 Source: This site
|
Serial No. |
Technical Parameter Items |
Specific Content |
|
1 |
Product Operating Voltage |
DC12V/24V |
|
2 |
Operating Temperature Range |
-40℃ - 101℃ |
|
3 |
Product Protection Class |
IP67 |
|
4 |
Relationship Between Air Pressure, Circuit and Alarm Light |
Under standard environment, when the air pressure is lower than 511 ± 40 (kPa), the circuit is connected and the alarm light is on; when it is higher than 511 ± 40 (kPa), the circuit is disconnected and the alarm light is off |
|
5 |
Insulation Requirement |
The insert and the shell must be insulated, and the insulation resistance should be greater than 1MΩ |
|
6 |
Shell Material |
HPb59 - 1 |
|
7 |
Air - tightness Requirement |
No air leakage between the shell and the outer casing |
|
8 |
Reference Standard |
QC/T217 - 2007 |